Montreal Front Right Left conv. 1200x400x308mm - HM 1120 - 3x low glass
PDF
Montreal Front Right Left conv. 1200x400x308mm - HM 1120 - 3x low glass
PDF
Fil
Rediger
Vis
Hjælp
Del på...
Log på
Opret en konto
Side
1
af 4
Rediger PDF
Tegn
Fremhæv
Tilføj tekst
Kommentar
155 %
Vil du gøre mere med denne fil?
Log på
Opret en konto
Hybrid
Mist
1120
deco
flame®
Montreal
H
ybrid
Mist
1120
FT900
Open
to
front,
right
and
left
1200x400x308mm,
Black
with
remote
control,
control
panel,
bluetooth
/
App
and
six
step
flame
levels
3x
110mm
low
glass
Wall
cut-out
"1200x410x313mm"
ATTENTION
Reservations
are
made
for
glass
tolerances
both
in
length
and
height
of
±
2.5mm
and
in
thickness
of
±
0.3mm
according
to
DS/EN
12150.
REVISION:
Order
Number
-
Customer
-
Reference:
SCALE:
1:10
Page
1
OF
4
FORMAT:
A3
Dimensions
are
in
millimeters
Customer
Approval
Signature
-
Date
PRINCIP
Montreal
Front
Right
Left
conv.
1200x400x308mm
-
H
M
1120
-
3x
low
glass
JDR
Copyright
of
Decoflame
ApS
Denmark,
whose
property
this
document
remains.
No
part
thereof
may
be
disclosed,
copied,
duplicated
or
in
any
other
way
made
use
of,
except
with
the
approval
of
Decoflame
ApS.
DecoFlame
ApS
Vang
Mark
2
9380
Vestbjerg
TLF:
+45
96
30
48
00
04-04-2024
www.decoflame.com
Author:
Date
-
Cut-out
410
mm
min.
210
mm
Recess
45mm
Cut-out
1200mm
Cut-out
313mm
Recess
Centered
1100mm
Recess
min.
300mm
The
wall
cut-out
is
covered
with
non
flammable
material
e.g
fiber
plaster
boards
or
bricks.
Power
Supply
in
bottom
of
recess
Cut-out
410
mm
Cut-out
1200mm
A
A
B
Electricity
Supply
The
deco
flame®
Hybrid
Mist
needs
to
be
connected
to
the
mains.
Make
sure
there
is
a
power
socket
for
230V
-
50-60
Hz
Cut-out
313mm
C
SECTION
A-A
5
mm
gap
In
order
to
cool
the
fireplace
and
ensure
sufficient
air
flow
DO
NOT
seal
the
gap
300
mm
min.
5
mm
210mm
45mm
DETAIL
C
SCALE
1
:
5
Wall
dimensions
DETAIL
B
REVISION:
Order
Number
-
Customer
-
Reference:
SCALE:
1:10
Page
2
OF
4
FORMAT:
A3
Dimensions
are
in
millimeters
Customer
Approval
Signature
-
Date
PRINCIP
Montreal
Front
Right
Left
conv.
1200x400x308mm
-
H
M
1120
-
3x
low
glass
JDR
Copyright
of
Decoflame
ApS
Denmark,
whose
property
this
document
remains.
No
part
thereof
may
be
disclosed,
copied,
duplicated
or
in
any
other
way
made
use
of,
except
with
the
approval
of
Decoflame
ApS.
04-04-2024
Author:
Date
-
400
Glass
110mm
mm
1200mm
Burner
900mm
Safety
chamber
1086mm
27
mm
Fix
points
1
2
3
308mm
177mm
200mm
Exploded
view
showing
the
installation
process.
1.
The
chassis
of
the
fireplace
(top/sides/bottom)
is
centered
in
the
wall
cut-out.
Use
suited
wall
plugs
depending
on
the
type
of
wall.
2.
The
fireplace
is
plugged
in
the
power
outlet
and
lowered
into
the
recess.
3.
Gently
place
the
glass
on
the
base
plate
pins.
General
Installation
Guidelines
for
“deco
flame®
made
to
measure
fireplaces":
The
wall
cut-out
is
made
at
least
5mm
deeper
than
the
depth
of
the
fireplace
to
ensure
sufficient
air
flow
and
cooling
of
the
fireplace.
Furthermore,
it
is
essential
to
maintain
a
5mm
gap
all
the
way
around
the
fireplace
(Cut-out
=
Fireplace
Dimensions
+
10mm)
This
gap
must
not
be
sealed.
As
the
edges
of
the
cut-out
remain
visible
it
is
important
that
they
are
done
to
the
highest
possible
finish.
All
four
corners
of
the
cut
out
must
have
exactly
a
90
degree
angle.
Plasterboard
walls
-
Stud-walls
All
surfaces
inside
the
wall
cut-out
are
to
be
covered
with
fibre
plaster
sheets
or
other
non-inflammable
materials.
Stone/Brick
walls
The
cut-out
is
made
according
to
the
attached
drawing.
Important
Make
sure
to
create
a
closed
cavity
for
the
section
below
the
base
plate
of
the
fire
and
above
the
roof
of
the
fireplace.
Installation
process
REVISION:
Order
Number
-
Customer
-
Reference:
SCALE:
1:10
Page
3
OF
4
FORMAT:
A3
Dimensions
are
in
millimeters
Customer
Approval
Signature
-
Date
PRINCIP
Montreal
Front
Right
Left
conv.
1200x400x308mm
-
H
M
1120
-
3x
low
glass
JDR
Copyright
of
Decoflame
ApS
Denmark,
whose
property
this
document
remains.
No
part
thereof
may
be
disclosed,
copied,
duplicated
or
in
any
other
way
made
use
of,
except
with
the
approval
of
Decoflame
ApS.
04-04-2024
Author:
Date
-
IMPORTANT
INFORMATION
Particulars
of
the
wall
in
which
the
fireplace
shall
be
installed
DO!
install
the
fireplace
in
a
massive
wall
(made
of
bricks,
stone
or
gas
beton)
using
the
wall
cut-out
dimensions
mentioned
on
the
previous
page.
DO!
install
the
fireplace
in
an
open-wall
construction,
which
is
closed
above
and
below
the
fireplace.
Make
sure
to
create
a
closed
cavity
for
the
section
below
the
base
plate
of
the
fire.
DO
NOT!
install
the
fireplace
in
a
wall
construction
which
is
open
above
and
below
the
fireplace.
The
warm
air
will
cause
turbulences
inside
this
hollow
construction
which
will
have
a
negative
impact
on
the
flames.
REVISION:
Order
Number
-
Customer
-
Reference:
SCALE:
1:10
Page
4
OF
4
FORMAT:
A3
Dimensions
are
in
millimeters
Customer
Approval
Signature
-
Date
PRINCIP
Montreal
Front
Right
Left
conv.
1200x400x308mm
-
H
M
1120
-
3x
low
glass
JDR
Copyright
of
Decoflame
ApS
Denmark,
whose
property
this
document
remains.
No
part
thereof
may
be
disclosed,
copied,
duplicated
or
in
any
other
way
made
use
of,
except
with
the
approval
of
Decoflame
ApS.
04-04-2024
Author:
Date
-